Energy & Workshop Math

Wire Size Calculator – Voltage-Drop Comparison

Compare listed reference gauges against a chosen voltage-drop limit.

Units

Your measurements

Results update as you type.

Three-phase: line-to-line RMS voltage.

Fractions and number formats

Use decimals (12.5), fractions (12 1/2 or 12-1/2), or explicit lengths (12ft 6in, 12′ 6″, 25 mm). A comma followed by one or two digits is a decimal comma: 12,5 = 12.5. Grouped commas mean thousands: 1,200 = 1200. Use a decimal point for ambiguous values. Scientific notation is not accepted.

Enter your measurements

Results update as you type.

About this calculator

Find the smallest listed Southwire reference gauge meeting a voltage-drop limit for the run. This comparison does not establish a safe conductor size: ampacity, temperature, protection and installation must also be checked.

How to measure

  • Measure the one-way run length from supply to load.
  • Read the continuous load current and supply voltage.
  • For AC, note the power factor and select 3% or 5%.
  • Confirm ampacity and termination ratings separately.

How to use this calculator

  1. Choose DC, single-phase or balanced three-phase.
  2. Enter current, one-way length and supply voltage.
  3. Pick the reference conductor material and a comparison drop limit; 3% and 5% are not universal code limits.
  4. For AC, enter the lagging power factor.
  5. Read the smallest reference gauge meeting the drop limit. Have a qualified electrician check ampacity, derating, protection, terminations and applicable local requirements separately.

Formula

DC drop = 2 × length × current × resistance

AC drop ≈ circuit factor × length × current × (resistance × PF + reactance × sin(acos(PF)))

Choose the first gauge whose drop ÷ supply ≤ your limit

Receiving voltage = supply − drop

Assumptions

  • Reference data is for the named Southwire product series at 75°C. Its 60 Hz reactance assumes the cited non-ferrous conduit and conductor spacing; other cables, frequencies and arrangements require matched data.
  • AC reactance is at 60Hz; AC estimates use a balanced, lagging-power-factor approximation.
  • The simplified AC projection is supported only when the total series-voltage magnitude is at most 10% of supply. This is a software model limit, not a code or safety limit. Outside it, full circuit/phasor analysis is required.

What the comparison checks

What the comparison checks
ItemIncluded?
Chosen voltage-drop limitYes
Conductor ampacity / deratingNo
Breaker and termination ratingsNo
Local installation complianceNo

The displayed gauge is a reference-product voltage-drop comparison only.

Common mistakes

  • Treating the smallest listed voltage-drop gauge as a safe installation size.
  • Using a universal 3% or 5% code claim.
  • Ignoring conductor temperature, installation conditions and protection.

Worked example

Try it: press “Load example” above the form.

20 A over 30 m at 12 V DC with a 3% comparison limit selects reference 3/0 copper at 75°C. This is a voltage-drop comparison, not ampacity approval.

Limitations

Educational reference-gauge comparison for voltage drop only. The displayed gauge is not a safe or compliant installation size. A qualified electrician must separately assess ampacity, temperature, protection, terminations and applicable requirements. The simplified AC projection is supported only when the total series-voltage magnitude is at most 10% of supply. This is a software model limit, not a code or safety limit. Outside it, full circuit/phasor analysis is required.

Frequently asked questions

What does minimum conductor mean here?

It is the smallest gauge in the listed reference product series meeting the selected voltage-drop limit. It is not the minimum legal or thermally safe conductor size.

Can I treat 3% or 5% as universal code limits?

No. They are comparison limits in this tool. Applicable requirements depend on circuit type, jurisdiction and installation. Have the full design checked rather than choosing cable from a voltage-drop result alone.

What does the worked example show?

20 A over 30 m at 12 V DC with a 3% comparison limit selects reference 3/0 copper at 75°C. This is a voltage-drop comparison, not ampacity approval.

Which assumptions should I check before using the result?

Educational reference-gauge comparison for voltage drop only. The displayed gauge is not a safe or compliant installation size. A qualified electrician must separately assess ampacity, temperature, protection, terminations and applicable requirements.

Reviewed by Codex AI editorial agent (Editorial, 2026-11-12) · Codex independent specialist-review AI agent (educational arithmetic/source review; not licensed human approval) (Electrical, 2026-11-12).

Sources

Sources explain the methods and any named product presets. Check your product label where coverage, yield or density differs.

Calculation documentation · Updated 2026-11-12 · Version 1.6.4. Estimates are planning aids. Confirm quantities, coverage and prices with your supplier before purchasing. Found an error? Report it.