Energy & Workshop Math
AC Size Calculator
Estimate room air-conditioner capacity from floor area and conditions.
Enter your measurements
Results update as you type.
About this calculator
Choose room air-conditioner capacity using ENERGY STAR's room-size bands, then adjust for ceiling height, sun exposure, occupants and a kitchen. The result is a planning estimate for a single room or zone.
How to measure
- Measure the floor area of the room to be conditioned.
- Note ceiling height, window sun exposure, occupants and any kitchen.
- Match to a nominal equipment size at or above the estimate.
How to use this calculator
- Measure the room's floor area.
- Confirm the ceiling height and sun exposure.
- Add occupants and a kitchen if they apply.
- Compare available capacities with an installer; an oversized unit can dehumidify poorly.
Formula
Base BTU/h from ENERGY STAR room bands: 100–150 ft² 5,000; 250 6,000; 300 7,000; 350 8,000; 400 9,000; 450 10,000; 550 12,000; 700 14,000; 1,000 18,000; 1,200 21,000; 1,400 23,000; 1,500 24,000; 2,000 30,000; 2,500 34,000. Areas below 100 ft² or above 2,500 ft² are outside this chart.
Adjusted BTU/h = base × (ceiling height ÷ 8) × exposure factor
Add 4,000 BTU/h for a kitchen and 600 BTU/h per occupant above two
Tons = BTU/h ÷ 12,000
Assumptions
- The base bands follow ENERGY STAR room air-conditioner sizing guidance for typical spaces.
- Sun, occupant and kitchen adjustments follow the cited room guidance. Ceiling-height scaling is an additional simple volume assumption.
- The space is a single room or zone, not a whole house.
Selected ENERGY STAR room chart bands
| Room area, upper band limit | Base capacity |
|---|---|
| 400 ft² | 9,000 BTU/h |
| 700 ft² | 14,000 BTU/h |
| 1,000 ft² | 18,000 BTU/h |
| 1,200 ft² | 21,000 BTU/h |
Selected entries from the cited 100–2,500 ft² room chart, before adjustments. No estimate is supplied outside that area range. Not a whole-house load calculation.
Common mistakes
- Using the room chart above its supported area range.
- Treating the optional ceiling-height rule as part of the published chart.
- Oversizing an air conditioner without checking humidity control.
Worked example
Try it: press “Load example” above the form.
A 400 ft² room at 8 ft with mixed exposure estimates 9,000 BTU/h, equal to 0.75 refrigeration ton.
Limitations
Not a Manual J load calculation. Room shape, wall construction, glazing, floor level and climate affect the real load; seer2/efficiency and noise are separate choices.
Frequently asked questions
How many BTU/h does a 400 ft² room need?
The cited ENERGY STAR base chart gives 9,000 BTU/h for a room up to 400 ft². That is 0.75 refrigeration ton. Shade, occupants and a kitchen can change the comparison.
Should I always buy the next larger air conditioner?
No. Oversizing can reduce dehumidification and comfort. Use the room chart as a starting point, then confirm the actual equipment selection with a qualified installer.
What does the worked example show?
A 400 ft² room at 8 ft with mixed exposure estimates 9,000 BTU/h, equal to 0.75 refrigeration ton.
Which assumptions should I check before using the result?
Not a Manual J load calculation. Room shape, wall construction, glazing, floor level and climate affect the real load; seer2/efficiency and noise are separate choices.
Sources
Sources explain the methods and any named product presets. Check your product label where coverage, yield or density differs.
- ENERGY STAR: room air conditioner sizing
Room-size capacity bands and installation guidance; used as a planning chart, not a load calculation.
Calculation documentation · Updated 2026-11-11 · Version 1.6.4. Estimates are planning aids. Confirm quantities, coverage and prices with your supplier before purchasing. Found an error? Report it.
Related calculators
All Energy & Workshop Math calculatorsBTU Calculator
Estimate room cooling BTU per hour from area and simple adjustments.
Open →CFM Calculator
Convert cooling capacity to airflow, or size room airflow from volume and ACH.
Open →Air Changes Per Hour Calculator
Compute ACH from room volume and airflow, in cubic metres per hour or CFM.
Open →Watts to Amps Calculator
Convert real power in watts to load current for DC, AC single-phase or balanced three-phase circuits.
Open →Amps to Watts Calculator
Convert load current in amps to real power in watts for DC, AC single-phase or balanced three-phase circuits.
Open →Battery Runtime Calculator
Estimate how long a battery will run a load, with explicit usable-energy and efficiency assumptions.
Open →